  • 4-channel digital amplifier

  • Three models with different Input modules:
    PA 4400 with 4 × line IN symmetrical
    PA 4400 CINCH with 4 × line IN cinch asymmetrical
    PA 4400 DANTE with Dante interface

  • 4 × 400 watts / 2 × 800 watts output power at 2 – 8 ohms

  • Second slot for additional input module

  • VCA inputs per channel

  • Switchable Automatic On/Off per channel

  • On/Off- and Fault contact

  • Switchable input sensitivity +4/-6 dBU per channel

  • Silent running regulated fans

  • Switchable Ground Lift per input channel pair

  • 1U chassis, installation depth only 348 mm

  • Optional:
    4×IN-SYM input module 4 × line IN symmetrical
    4×IN-CINCH input module 4 × line IN asymmetrical
    DANTE 8×8 8-channel Dante input module
    • 100 V transformer
    • Volume control (wall-panel WP-V or rack-panel RP-V)
    • DV module for volume control via Up/Down contacts

Fields of application
  • Home audio
  • Media rooms
  • Conference rooms
  • Shops, sales rooms
  • Gastronomy
  • Clubs, discotheques
  • Concert halls, theatres
  • Churches
Description

The PA 4400 is a sophisticated, class-D multi-channel power amplifier with four channels and two sockets for different input modules. The three different models in this series are equipped with symmetrical line inputs, asymmetrical cinch inputs or an Dante module, and can be expanded by adding a second input module. By combining two input modules, the power amplifier can be operated as a central amplifier unit with a mix of analog and digital signal sources. Ground Lift switch for each input channel pair plus dip switches for modifying input sensitivity on each channel enable the amplifier to be easily adjusted to different signal sources.

The PA 4400 circuits are designed to ensure outstanding sound quality and safety levels with minimum heat build-up. The generously proportioned, high-capacity mains adapter together with our new processor-controlled class-D power amplifier modules guarantee outstanding efficiency levels and enormous power reserves. The Automatic On/Off function (switchable for each channel) automatically switches inactive amplifier channels to an energy-saving Sleep mode. The power amplifier has an output rating of
4 × 400 watts at 2 - 8 ohms or 2 × 800 watts at 4 - 16 ohms in bridge mode.

The front features LED for On/Standby, LEDs per each channel for Protect, Limit, Signal, Sleep and LED Bridge per each channel pair as well as gain controllers for each channel. To enable remote control, the amplifiers are equipped with an On/Off contact and VCA inputs with separate channels for external volume control. All outputs can be controlled independently or in groups using our WP-V and RP-V volume controllers or the DV module via Up/Down contacts. Any fault in the power amplifier channels is signaled via the isolated fault contact.

Technical data
Inputs 4 × Line IN sym. / 4 × Line IN cinch asym. / Dante (depending on the model)
Nom. input/
output level
+4/-6 dBU, switchable
Max. input /
output level
+ 22 dBU
Input impedance 20 kohms
Load impedance ≥ 2 ohms / bridge ≥ 4 ohms
Outputs 4 × Speaker OUT up to 2 × 4 mm²
(screwtype terminals, pluggable)
Output power
2 ohms
4 ohms
8 ohms
Bridge

4 × 400 watts
4 × 400 watts
4 × 400 watts
2 × 800 watts (4 - 16 ohms)
Frequency range 15 Hz – 20 kHz
Dynamic range > 100 dB
Displays LED for ON / STANDBY; LEDs per channel for PROTECT, LIMIT, SIGNAL, SLEEP; LED BRIDGE per each channel pair
Controls Gain control and power switch at front. Dip switches AUTO ON/STEADY ON and SENSITIVITY +4/-6 dBU per channel and Dip switches PARALLEL and BRIDGE for each channel pair at back
Additional connectors VCA inputs 0 – 10 V for each channel (also for DV modules), floating Fault contact (N/O), Standby contact (N/O or N/C)
Cooling Silent running regulated fans, air flow from front to back
Protective circuits Inrush current limiter, peak limiter, current limiter and power limiter for each speaker output, short circuit and multilevel overtemperature protection for all internal channels
Power supply 230 VAC
Mains connector IEC connector
Power consumption
Standby
All channels SLEEP
All channels active
1/8 Nom. power
Max. power
consumption
Peak power

0.5 watts
12 watts
28 watts
264 watts
440 watts

2440 watts
Dimensions
(W × H × D)
19", 1U,
483 × 44 × 348 mm
Weight 10 kg
Warranty 5 years
Downloads
Data sheet (PDF)
Produktbrochure
 
ModelVersion
PA 4400
Order No.: 3106-0028
4 × Line In Sym., 4 × 400 W / 2 – 8 ohms, 1 U
PA 4400 CINCH
Order No.: 3106-0029
4 × Line In Cinch
PA 4400 DANTE
Order No.: 3106-0030

Dante Interface,
2 × RJ-45 Ethernet
(Primary/Secondary)

Accessories
4×IN-SYM
Order No.: 3108-0002

4-channel input module for the PA series / PA DSC series with symmetrical line inputs. The module features GROUND LIFT dip switches for each channel pair.

4×IN-CINCH
Order No.: 3108-0006

4-channel input module for the PA series / PA DSC series with asymmetrical cinch inputs. The module features GROUND LIFT dip switches for each channel pair.

DANTE 8×8
Order No.: 3108-0009

8-channel Dante input module for the PA series / PA DSC series. The Dante interface features two RJ45 terminals for audio over Ethernet (primary/secondary).

WP-V
Order No.: 3401-0002
Wall panel, volume control for amplifiers of the PA Series for surface boxes.
RP-V
Order No.: 3402-0002
Rack panel, volume control for amplifiers of the PA Series to install in 19“rack mount RP-1U.
RP-1U
Order No.: 3402-0016
19“ Rack mount, 1U, for 6 × RP panels
DV-Module
Order No.: 3109-0006
Digital volume control for amplifiers of the PA Series.
PA-T 400
Order No.: 3109-0004
100 V transformer module, 200 watts, toroidal core
PA-T 1U
Order No.: 3109-0005
Rack cradle 19“, 1U for 4 × PA-T 100, 2 × PA-T 200, 2 × PA-T 400